No
|
Item designation
|
Regulation Marpol 73/78 as amended where ‘type-approval’ is required
|
Applicable regulations of Marpol 73/78, as amended, and the relevant resolutions and circulars of the IMO
|
Testing standards
|
1 |
2 |
3 |
4 |
5 |
A.2/3.1
|
Non-portable and transportable extinguishers |
Regulation II-2/6.1, II-2/7.1.3, II-2/7.2.3, II-2/ 7.3.1, Regulation X/3
|
Regulation II-2/6.1, II-2/7.1.3, II-2/7.2.3, II-2/ 7.3.1, IMO Resolution MSC.36(63) 7.5.6.11.2, 7.5.6.11.3 (1994 HSC Code) |
EN 1866 (1998) ISO 11601 (1999) |
Regulation II-2/10.5.1.2.2, II-2/10.5.2.2.2, II-2/10.5.3.2.1, Regulation X/3, IMO Resolution MSC. 98 (73) Chapter 4.1.2 (FSS Code) |
Regulation II-2/10.5.1.2.2, II-2/10.5.2.2.2, II-2/10.5.3.2.1, IMO Resolution MSC.97(73) 7.5.6.11.2, 7.5.6.11.3 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 4.1.2 (FSS Code) |
A.2/3.2
|
Nozzles for fixed pressure water-spraying fire-extinguishing systems for special category spaces |
Moved to A.1/3.49
|
A.2/3.3
|
Cold-weather starting of generator sets (starting devices) |
Regulation II-1/44.2, Regulation X/3 |
Regulation II-1/44.2, IMO Resolution MSC.36(63) 12.4 (1994 HSC Code) |
|
Regulation II-1/44.2, IMO Resolution MSC.97(73) 12.4 (2000 HSC Code) |
A.2/3.4
|
Dual purpose type nozzles (spray/jet type) |
Regulation II-2/4.8.4, II-2/41-2.1.5, Regulation X/3 |
Regulation II-2/4.8.4, II-2/41-2.1.5 IMO Resolution MSC.36(63) 7.7.8.6 (1994 HSC Code) |
|
Regulation II-2/10.2.3.3.4, Regulation X/3 |
Regulation II-2/10.2.3.3.4, IMO Resolution MSC.97(73) 7.7.5.6 (2000 HSC Code) |
A.2/3.5
|
Fixed fire detection and fire alarm systems components for control stations, service spaces, accommodation spaces, machinery spaces and unattended machinery spaces |
Regulation II-2/13, II-2/14.1, Regulation X/3 |
Regulation II-2/13, II-2/14.1 IMO Resolution MSC.36 (63) 7.7.1 (1994 HSC Code) |
EN 54-2 (1997) + AC (1999) EN 54-4 (1997) + AC (1999) |
Regulation II-2/7.2.2, II-2/7.4, II-2/7.4.1 Regulation X/3 IMO Resolution MSC.98(73) Chapter 9 (FSS Code) |
Regulation II-2/7.2.2, II-2/7.4, II-2/7.4.1 IMO Resolution MSC.97(73) 7.7.1 (2000 HSC Code) IMO Resolution MSC.98(73) Chapter 9 (FSS Code) |
A.2/3.6
|
Smoke detectors |
Regulation II-2/13.3.2, Regulation X/3 |
Regulation II-2/13.3.2, IMO Resolution MSC.36(63) 7.7.1 (1994 HSC Code) |
EN 54-7 (2000), pr EN 54-12, pr EN 54-15 |
Regulation II-2/7.2.2, II-2/7.4 Regulation X/3, IMO Resolution MSC.98(73) Chapter 9.2.3.1.2 (FSS Code) |
Regulation II-2/7.2.2, II-2/7.4, IMO Resolution MSC.97(73) 7.7.1 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 9.2.3.1.2 (FSS Code) |
A.2/3.7
|
Heat detectors |
Regulation II-2/13.3, Regulation X/3 |
Regulation II-2/13.3.3, IMO Resolution MSC.36(63) 7.7.1 (1994 HSC Code) |
EN 54-5 (2000), EN 54-6 (1982) + A1 (1998), pr EN 54-15 |
Regulation II-2/7.2.2, II-2/7.4 Regulation X/3, IMO Resolution MSC.98(73) Chapter 9.2.3.1.3 (FSS Code) |
Regulation II-2/7.2.2, II-2/7.4, IMO Resolution MSC.97(73) 7.7.1 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 9.2.3.1.3 (FSS Code) |
A.2/3.8
|
Electric safety lamp |
Regulation II-2/17.1.1.4, Regulation X/3 |
Regulation II-2/17.1.1.4, IMO Resolution MSC.36(63) 7.10.3.1.4 (1994 HSC Code) |
IEC Publication 79 |
Regulation II-2/10.10, Regulation X.3, IMO Resolution MSC.98(73) Chapter 3.2.1.1.4 (FSS Code) |
Regulation II-2/10, IMO Resolution MSC.97(73) 7.10.3.1.4 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 3.2.1.1.4 (FSS Code) |
A.2/3.9
|
Protective clothing resistant to chemical attack |
Moved to A.1/3.50
|
A.2/3.10
|
Low-location lighting systems |
Moved to A.1/3.40 |
A.2/3.11 ex
A.1/3.10
|
Nozzles for fixed pressure water spraying fire extinguishing systems for machinery spaces |
Regulation II-2/10.1, Regulation X/3 |
Regulation II-2/10.1, IMO Resolution MSC.36(63) 7.7.4 (1994 HSC Code) |
|
Regulation II-2/10.4, IMO Resolution MSC.98(73) Chapter 7 (FSS Code). NB Not included in the 2000 HSC Code |
Regulation II-2/10.4, IMO Resolution MSC.98(73) Chapter 7 (FSS Code) |
A.2/3.12
|
Equivalent fixed gas fire extinguishing systems for machinery spaces and cargo pump rooms |
Moved to A.1/3.45
|
A.2/3.13
|
Compressed airline breathing apparatus |
Regulation II-2/17.1.2, Regulation X/3 |
Regulation II-2/17.1.2, IMO Resolution MSC.36 (63) 7.10.3.2.1 (1994 HSC Code) |
EN 139 (1994) + AC (1995) + A1 (1999) |
Regulation II-2/10.10.1, Regulation X/3, IMO Resolution MSC.98(73) Chapter 3 (FSS Code) |
Regulation II-2/10.10.1, IMO Resolution MSC.97(73) 7.10.3.2.1 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 3 (FSS Code) |
A.2/3.14
|
Fire hoses (reel type) |
Regulation II-2/4.7.1, Regulation X/3 |
Regulation II-2/4.7.1, IMO Resolution MSC.36 (63) 7.7.8.5 (1994 HSC Code) |
EN 671-1 (1994) + AC (1995) |
Regulation II-2/10.2.3.1.1, II-2/10.2.3.3.2, Regulation X/3 |
Regulation II-2/10.2.3.1.1, II-2/10.2.3.3.2, IMO Resolution MSC.97(73) 7.7.5.5 (2000 HSC Code) |
A.2/3.15
|
Sample extraction smoke detection systems components |
Regulation II-2/13-1 |
Regulation II-2/13-1 |
|
Regulation II-2/7.6, II-2/19.3.3, II-2/20.4.2, IMO Resolution MSC.98(73) Chapter 10 (FSS Code) |
Regulation II-2/7.6, II-2/19.3.3, II-2/20.4.2, IMO Resolution MSC.98(73) Chapter 10 (FSS Code) |
A.2/3.16
|
Flame detectors |
Regulation II-2/132, Regulation X/3 |
Regulation II-2/13, IMO Resolution MSC.36 (63) 7.7.1 (1994 HSC Code) |
Pr EN 54-10 |
Regulation II-2/7.1, II-2/7.2.2, Regulation X/3, IMO Resolution MSC.98(73) Chapter 9.2.3.1.1 (FSS Code) |
Regulation II-2/7.1, II-2/7.2.2, IMO Resolution MSC.97(73) 7.7.1, 7.7.1..5 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 9.2.3.1.1 (FSS Code) |
A.2/3.17
|
Manual call points |
Regulation II-2/13, Regulation X/3 |
Regulation II-2/13, IMO Resolution MSC.36 (63) 7.7.1 (1994 HSC Code) |
Pr EN 54-11 |
Regulation II-2/7.1, II-2/7.2.2, Regulation X/3, IMO Resolution MSC.98(73) Chapter 9.2.1.1 (FSS Code) |
Regulation II-2/7.1, II-2/7.2.2, IMO Resolution MSC.97(73) 7.7.1 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 9.2.1.1 (FSS Code) |
A.2/3.18
|
Alarm devices |
Regulation II-2/13, Regulation X/3 |
Regulation II-2/13, IMO Resolution MSC.36 (63) 7.7.1 (1994 HSC Code) |
Pr EN 54-3 (2001) |
Regulation II-2/7.1, II-2/7.2.2, Regulation X/3, IMO Resolution MSC.98(73) Chapter 9.2.5 (FSS Code) |
Regulation II-2/7.1, II-2/7.2.2, IMO Resolution MSC.97(73) 7.7.1 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 9.2.5 (FSS Code) |
A.2/3.19
|
Fixed water based local application fire fighting systems components for use in category ‘A’ machinery spaces |
Moved to A.1/3.48
|
A.2/3.20
|
Upholstered furniture |
Moved to A.1/3.20
|
A.2/3.21 (New item) |
Paint lockers and flammable liquid lockers fire extinguishing systems components |
Regulation II-2/18.7 |
Regulation II-2/18.7 |
IMO MSC/Circ 847 |
Regulation II-2/10.6.3 |
Regulation II-2/10.6.3 |
A.2/3.22 (New item) |
Galley exhaust duct fixed fire extinguishing systems components |
Regulation II-2/16.7.4, II-2/32.1.9.3 |
Regulation II-2/16.7.4, II-2/32.1.9.3 |
|
Regulation II-2/9.7.5 |
Regulation II-2/9.7.5 |
A.2/3.23 (New item) |
Helicopter deck fire extinguishing systems components |
Regulation II-2/18.8.2.3 |
Regulation II-2/18.8.2.3 |
IMO Resolution A.855(20) |
Regulation II-2/18.1.2 |
Regulation II-2/18.1.2 |
A.2/3.24 (New item) |
Portable foam applicator units |
Regulation II-2/6.4, Regulation X/3 |
Regulation II-2/6.4, IMO Resolution MSC. 36(63) 7.8.4.1.2 (1994 HSC Code) |
|
Regulation X/3 |
IMO Resolution MSC. 97(73) 7.8.4.1.2 (2000 HSC Code), IMO Resolution MSC.98(73) Chapter 4.1.2 (FSS Code) |
A.2/3.25 (New item) |
C class divisions |
Regulation II-2/3.5 |
Regulation II-2/3.5 |
IMO Resolution A.799(19), IMO Resolution A.653(16), IMO Resolution MSC.61(67) Annex 1 Parts 1, 2 and 5 and Annex 2, ISO 1716 (1973) |
Regulation II-2/3.10 |
Regulation II-2/3.5 |
A.2/3.26 (New item) |
Gaseous fuel systems used for domestic purposes (components) |
Regulation II-2/51 |
Regulation II-2/51 |
|
Regulation II-2/4.3 |
Regulation II-2/4.3 |
A.2/3.27 (New item) |
Fixed gas fire extinguishing systems (CO2) components
|
Regulation II-2/5.2, Regulation X/3 |
Regulation II-2/5.2, II-2/7.1.1.1, II-2/38.2.1, II-2/39.1, II-2/53.1, II-2/53.2.2.1, II-2/63.1.1 IMO Resolution MSC.36(63) 7.7.6.2, 7.15 (1994 HSC Code) |
Pr EN.12094, Parts 1—20 |
Regulation II-2/10.4.1.1.1, Regulation X/3 |
Regulation II-2/10.4.1.1.1, I-2/10.5.1.1, II-2/10.6.3.1.1, II-2/10.7.1.1.II-2/10.7.1.3, II-2/10.9.1.1 IMO Resolution 97(73) 7.7.3.3, 7.15,7.17.3.8.1 (2000 HSC Code) IMO Resolution MSC.98(73) Chapter 5.2.2 (FSS Code) |
A.2/3.28 (New item) |
Medium expansion foam fire extinguishing systems components — fixed deck foam for tankers |
Regulation II-2/61.4 |
Regulation II-2/61.4 |
IMO MSC/Circ 798 |
Regulation II-2/10.8.1 |
Regulation II-2/10.8.1, IMO Resolution MSC.98(73) Chapter 14 (FSS Code) |
A.2/3.29 (New item) |
Fixed low expansion foam fire extinguishing systems components for machinery spaces and tanker deck protection |
Regulation II-2/61.4 |
Regulation II-2/8, II-2/61.4 |
IMO MSC/Circ 582 and Corr. 1 |
Regulation II-2/10.8.1 |
Regulation II-2/10.8.1, IMO Resolution MSC.98(73) Chapter 6.2.3. Chapter 14 (FSS Code) |
A.2/3.30 (New item) |
Expansion foam for fixed fire extinguishing systems for chemical tankers |
IMO Resolution MSC.4(48) Chapter 11 paragraph 11.3 (IBC Code) |
IMO Resolution MSC.4(48) Chapter 11 paragraph 11.3 (IBC Code) |
IMO MSC/Circs 799, 582, 553 |